Das Relativgravimeter-Kalibriersystem Hannover für 10−4-Maßstabsbestimmungen

authored by
Ludger Timmen, Reinhard Falk, Gerald Gabriel, Alexander Lothhammer, Manuel Schilling, Detlef Vogel
Abstract

A best possible accuracy for the calibration of relative gravimeters is often required to achieve the objectives of state-geodetic and geo-scientific surveys. A scale inaccuracy for relative gravimeters of 1· 10−4 is striven for which allows, e. g., to detect small vertical movements of the Earth’s surface or to avoid misinterpretation of observations showing apparent variations due to uncertain calibration of the relative gravimeters. Recently, the Gravity Meter Calibration System Hannover has been improved with respect to its most important parts: the Harz calibration line (3 absolute gravimetric points) and the Vertical Gravimeter Calibration Line Hannover (VGCH, 20-storey building, 20 relative gravimetric points). For this Upgrade 2017, only “state-of-the-art” measurements with gravimeters from Scintrex (Canada) and ZLS Corporation (USA) have been used. For the two calibration lines, the Upgrade 2017 replaces the solution of 2004 which was based on measurements with LaCoste-Romberg instruments only. They were the measuring standard in the 70s and 80s. The older absolute gravity determinations in the Harz line have been completed with modern A10 observations in 2013. In the VGCH, the base connection 210– 370 (1st to 17th storey, elevator for transportation) has been obtained with a standard deviation of 11 nm/s2. The inaccuracy between adjacent points varies between 5 and 10 nm/s2 for the points below the 18th storey. The scale inaccuracy of the Harz calibration line as well as of the VGCH is estimated to be 2·10−4 (expanded uncertainty, confidence interval 95 %). A regular checking of the relative gravimeters with regard to instrumental air pressure effects and instrumentally caused scale instabilities is strongly recommended.

Organisation(s)
Institute of Geodesy
Leibniz Research Centre FZ:GEO
External Organisation(s)
Federal Agency for Cartography and Geodesy (BKG)
Leibniz Institute for Applied Geophysics (LIAG)
Type
Article
Journal
AVN Allgemeine Vermessungs-Nachrichten
Volume
125
Pages
140-150
No. of pages
11
ISSN
0002-5968
Publication date
2018
Publication status
Published
Peer reviewed
Yes
ASJC Scopus subject areas
Geography, Planning and Development, Civil and Structural Engineering, Earth and Planetary Sciences (miscellaneous)
Electronic version(s)
https://gispoint.de/artikelarchiv/avn/2018/avn-52018/4315-das-relativgravimeter-kalibriersystem-hannover-fuer-104-massstabsbestimmungen.html (Access: Open)
 

Details in the research portal "Research@Leibniz University"